PL-C004P
6/12 Volt 4.5 Amp Battery Charger
GENERAL INFORMATION
With auto memory function after Power restart
Full Power charging
6V / 12V 1A for motorcycle batteries
Selective mode for AGM and Winter condition
Fit for Lead Acid / AGM and Gel Batteries
INPUT
Input Voltage: 100-240VAC/50Hz
Input: CableWith Cable (Desktop Case)
Charging Battery Type: 12V Lead-Acid: 1.2AH – 120AH;
6V Lead-Acid: 1.2AH – 14AH
Restore Dead Battery Function: 6V &12V Battery
Abnormality Protection: Short Circuit; Battery Defective
and Reverse Connection
Charging Mode: 6 Steps With Fully
Automatic Switch Mode
Material Of Housing: UV Resistant Polycarbonate
Proof Water Grade: IP65
Approval: CE / GS
Application: Used in Car, Motorbike, Vehicles,
and Golf Buggies
SPECIFICATION
ODEL | PL-C004P | PL-C002P | PL-C001P |
Charging current (A) | 4.5Amp | 2Amp | 1Amp |
Charging voltage (V) | 6V / 12V | 6V / 12V | 6V/12V |
For battery: | |||
Open WET | √ | √ | √ |
Maintenance free | √ | √ | √ |
AGM/VRLA | √ | √ | √ |
Calcium | √ | ||
To charge battery capacity | 14Ah – 120Ah | 1.2Ah – 40Ah | 1.2-24Ah |
To maintain battery capacity | 14Ah – 150Ah | 1.2Ah – 60Ah | 1.2-24Ah |
Microprocessor controlled | √ | √ | √ |
Charging steps: | |||
Float charge | √ | √ | √ |
Overcharge protection | √ | √ | √ |
Allow for safe contiounus charge | √ | √ | √ |
Boost | |||
Recovery function | √ | √ | √ |
IP rating | |||
Charge Status indiations: | |||
Battery defect | √ | √ | √ |
Wrong connection | √ | √ | √ |
Wrong polarity | √ | √ | √ |
Short circuit | √ | √ | √ |
Charging progress indication | √ | √ | √ |
Full charge indication | √ | √ | √ |
230V power on | √ | ||
built-in protection | √ | √ | √ |
EMC free | √ | √ | √ |
Reversed polarity Protection | √ | √ | √ |
Short-circuit-protection | √ | √ | √ |
Spark free protection | √ | √ | √ |
Mechanical features | |||
Length of Dc cables | |||
Length of AC 230V cable | |||
DC charging clips fully insulated | |||
Material of housing | |||
Fire retardant material | |||
Dimensions | 193.5×66.4x46mm | 100x71x73mm | |
weight |
INSTRUCTION MANUAL
INTENDED USE
The product is designed to charge and maintain 6 or 12-V lead-acid batteries with a capacity of 1.2Ah – 120 Ah. The charger has been optimized to maintain the battery of your motorcycle or car when it is not being used over longer periods of time, for example over the winter. The charger is designed to charge Gel, AGM, and standard lead-acid batteries.
Any use other than that described above will damage this product and involves the risk of short circuits, fire, electric shock, etc.
PACKAGE CONTENTS
• Battery charger
• Operating instructions
• Cable with battery clamps
• Cable with o-ring connectors
• Cable with cigarette lighter plug
SAFETY INSTRUCTIONS
Please read through the operating instructions completely before operating the device. They contain important information for correct operation. The warranty/guarantee will be void if damage is incurred resulting from non-compliance with these operating instructions! We assume no liability for any consequential damage! We do not assume any liability for damage to property or personal injury caused by improper use or the failure to observe the safety instructions!
GENERAL
• The unauthorized conversion and/or modification of the product is inadmissible for safety and approval reasons (CE).
• The battery charger may only be operated with a supply voltage of 100-240 V~/50/60 Hz.
• The product is not a toy. It is not suitable for children. Pay particular attention when children are present!
• The product may only be set up, used or stored in places that are not accessible to children. Danger to life!
• This product is only suitable for charging 6 and 12V lead-acid batteries. Never use it to charge different rechargeable batteries (e.g. NiCd, NiMH, LiPo) or even normal batteries! There is a risk of fire and explosion!
• Maintenance, adjustments and repair work may only be carried out by a specialist/specialised workshop. Only use original spare parts to repair the device. Using other spare parts can lead to significant material damage or personal injury!
• Do not leave packaging material lying around carelessly. It might become a dangerous toy for children!
• If you notice any damage, do not use the battery charger anymore.
OPERATION
• Operation under adverse ambient conditions must be avoided under all circumstances. Adverse ambient conditions include: ambient temperatures above 40 °C, flammable gases, solvents, vapor’s, dust, and relative humidity above 80 %.
• Do not use the battery charger inside a vehicle. The battery charger must not be used in the vicinity of flammable substances or gases.
• Ensure that there is sufficient ventilation during operation. Never cover the battery charger or the connected battery.
• Never charge lead-acid batteries in containers or poorly ventilated rooms. Explosive gases can be generated during the charging process!
• Keep the battery charger as well as the battery away from ignition sources. Do not smoke while handling the battery charger or the battery! There is danger of explosion!
• Never operate the device immediately after it has been taken from a cold to a warm room. The condensation generated can cause malfunctions and there is also the risk of a deadly electric shock!
• Persons (including children) who have insufficient knowledge or experience in using the device or who are physically, sensorially or mentally handicapped may only use the device under the supervision of a person responsible for their safety. Children must be kept under supervision and may not play with the device.
• Check the battery voltage before starting the charging process, only 6 and 12 Volt batteries can be recharged.
Notes on rechargeable batteries
• Make sure you observe all safety instructions and charging instructions of the battery manufacturer.
• Before connecting the battery to the battery charger, disconnect the battery from any loads or cables (turn off the loads first!).
• Always disconnect the ground connection from the battery before disconnecting the positive terminal.
• Disconnect the battery from the battery charger before connecting any loads to the battery.
• When connecting or disconnecting the battery, sparks might be produced. Therefore, make sure there is sufficient ventilation!
• Observe the polarity when connecting the battery to the battery charger (red charger terminal = positive/+, black charger terminal = negative/-).
• Lead-acid batteries contain aggressive and corrosive acids. Avoid skin or eye contact with battery fluids! Never dismantle lead-acid batteries! On skin contact, clean the affected areas thoroughly with water and soap. On eye contact, rinse the effected eye immediately with clear and cold running water! Then consult a doctor immediately!
• Batteries must not be short-circuited or thrown into fire. Risk of fire and explosion!
DISPOSAL
At the end of its useful life, this product must not be disposed of together with normal household waste, but has to be dropped off at a Collection Centre for the recycling of electrical and electronic devices. This is indicated by the symbol on the product, on the instruction manual or on the packaging.
The materials of which this product is made are recyclable pursuant to their labelling. With the reuse, the recycling of the materials or other forms of scrap usage you are making an important contribution to the protection of the environment.
DESCRIPTION OF LEDS/FUNCTIONS
CHARGING A LEAD-ACID BATTERY
1. First make sure your lead-acid battery is a 6V or 12V battery. Do not charge
batteries with different operating voltages!
2. Disconnect all loads from the battery. If the battery is installed in a vehicle, turn off the ignition and any other loads. Observe the instructions and safety information of the vehicle to find out how the vehicle battery should be charged. Modern vehicles are equipped with sensitive electronic parts and controls that can be damaged if you do not proceed properly!
3. Connect the battery charger to the power supply (100-240 V~/50/60 Hz).
4. Now you can select a function using the mode button (11) . See the next chapter for a description of the individual operating modes.
5. Then, connect the battery charger to the battery with the correct polarity. If the polarity is not correct, LED 5 will be lit.
6. If the Charging loop is in short circuit, LED 6 will be lit.
7. This battery charger is equipped with an automatic memory function, i.e. whenever AC supply is connected, it starts in last selected mode.
8. After the charging process, disconnect the battery charger from the mains supply.
9. First remove the clamp from the negative terminal and then from the positive terminal.
OPERATING MODES
Mode 1: Winter mode (14.7 V +/- 0.25 V)
• This mode is suitable for all lead-acid batteries (also SLA, gel, and AGM) with a capacity above 25Ah at low ambient temperature.
• To select this mode, press the MODE button (11) until LED 1 (car and snow symbol) lights up. The charging process starts automatically (4.5A+/-10%), LED 1 is lit.
• When the battery is fully charged (14.7 V +/- 0.25 V), LED 9 lights up. The device automatically switches to maintenance charging.
Mode 2: Summer mode (14.4 V +/- 0.25 V)
• This mode is suitable for all lead-acid batteries (also SLA, gel, and AGM) with a capacity above 25Ah at normal ambient temperature.
• To select this mode, press the MODE button (11) until LED 2 (car & sun symbol) lights up. The charging process starts automatically (4.5A+/-10%), LED 2 is lit.
• When the battery is fully charged (14.4V +/- 0.25V), LED 9 lights up. The device automatically switches to maintenance charging.
Mode 3: 6V Motorcycle mode (7.2 V +/- 0.25 V)
• This mode is intended especially for 6V batteries with a capacity below 24Ah, e.g. for 6V motorcycle batteries.
• To select this mode, press the MODE button (11) until LED 3 (6V motorcycle symbol) lights up. The charging process starts automatically (1A+/-10%), LED 3 is lit.
• When the battery is fully charged (7.2V +/- 0.25 V), LED 9 lights up. The device automatically switches to maintenance charging.
Mode 4: Motorcycle mode (14.4 V +/- 0.25 V)
• This mode is intended especially for 12V batteries with a capacity below 24Ah, e.g. for 12V motorcycle batteries.
• To select this mode, press the MODE button (11) until LED 4 (12V motorcycle symbol) lights up. The charging process starts automatically (1A+/-10%), LED 4 is lit.
• When the battery is fully charged (14.4V +/- 0.25 V), LED 9 lights up. The device automatically switches to maintenance charging.
REGENERATION FUNCTION
This function is designed to regenerate deep-discharged batteries. It cannot be directly selected.
If a deep discharged rechargeable battery is connected to the charger, the regeneration mode is the first mode to start. Low charging current are used to try and bring the deep discharged rechargeable battery to a normal battery voltage again. When the battery reaches a normal voltage, the charger will continue charging using the regular process.
DEFECTIVE RECHARGEABLE BATTERIES
The charger recognizes defective rechargeable batteries automatically. In this case the selected charging programme will not be started. LED 6 is lit.
MODE SELECT
Press the MODE button (11) to activate or deactivate the selected mode.
CLEANING
- Disconnect the battery charger from the battery and the mains voltage before cleaning it.
- Clean the outside of the product with a clean, dry, and soft cloth.
- Do not use aggressive cleaning agents to avoid discoloration.